Freezewave Fat Remove Machine 3-Handle Big Screen for Body Forming Face Lifting

/Freezewave Fat Remove Machine 3-Handle Big Screen for Body Forming Face Lifting
  • Freezewave Fat Remove Machine 3-Handle Big Screen for Body Forming Face Lifting
Primary Competitive Advantages:
  • We are A Professional Beauty Machines & Medical Aesthetic Devices Company Operating Since 2004
  • Our Quality Guaranteed
  • We Ship Worldwide
  • Small Orders Accepted
  • OEM Design Approvals
  • All Payment Accepted
  • Freezewave Fat Remove Machine 3-Handle Big Screen for Body Forming Face Lifting, 3IN1 Freezewave Body Contouring Vertical Salon Cellulite Reduction Machine, 3 In 1 Freezewave Body Contouring Machine, Three Handles 3 in 1 Onda Coolwave Face Lift Device Freezewave Body Slimming Weight Loss Machine, 3 IN 1 Fat Freezing Machine With Laser, Newest Vertical 3 Handles 2450MHz FrezzeWave Machine China supplier factory

    Freezewave Fat Remove Machine 3-Handle Big Screen for Body Forming Face Lifting  Specification
    Part No.: BLS1502
    Power 800W
    Frequency 2450MHz
    Output Power 12J-82J
    Laser Wavelength 685nm
    Screen 15.6-inch touch screen
    Fuse 10A
    Voltage AC110V-220V
    N. W./G. W. 32kg/54kg
    Package Size 113cm x 63cm x 61cm

    (1) FREEZEWAVE
    1.Localized Fat Deposits: The deep-penetrating probe delivers energy deep into the tissue, disrupting the membranes of subcutaneous fat cells. The 2.dissolved fat is then expelled from the body through stimulated physiological metabolic processes (macrophage lipolysis).
    Cellulite: Precisely targets the connective septa between fat lobules in advanced cellulite (where the typical “orange peel effect” is visible).
    3.Skin Tightening: Unique microwave energy instantly contracts dermal collagen fibers while stimulating new collagen production, resulting in firmer, more elastic tissue.
    Utilizing microwave energy to reduce stubborn fat, tighten skin, and smooth cellulite. Safe and effective with no downtime.

    (2) Laser
    It promotes inflammation absorption and wound repair, and can provide effective treatment for inflammatory, neurological and traumatic pain in humans. It can be used for conditions such as frozen shoulder, cervical spondylosis, lumbar muscle strain, acupuncture point irradiation and skin beauty.
    Helps break down fat.

    (3) Treatment Cycle
    FREEZEWAVE
    Treatment duration varies by area. Facial and neck areas take 8 – 12 minutes, while body areas require 20 – 30 minutes.
    Treatment course: 1 – 2 times per week, with 8 – 12 sessions constituting one treatment course. The number of sessions depends on individual goals and the specific treatment area.

    Laser
    25 – 30 minutes for a single session. Ten sessions for a course of treatment with an interval of two days.

    Cautions for FREEZEWAVE
    (1) Treatment can be performed on areas with abundant facial muscles, such as the cheekbones, neck, and chin. Treatment should not be performed around the eyes.
    (2) Remove the handle from the accessory rack before activating it to prevent microwave interference. Because the handle has a relatively strong energy output, activating it first may cause microwave interference.
    (3) After activating the handle, do not touch the white section in the center with your fingertips, as microwave energy may concentrate on your fingertips and cause pain.
    (4) During treatment, do not hold the handpiece in one position for too long; move it slowly.
    (5) To get the best result, it is recommended to avoid any moisturizer or emollient on the treatment area for 48 hours prior to each session.
    (6) To assist with lymphatic drainage, increase your water intake significantly on the day of treatment, as well as the day before and after treatment. Maintaining a healthy lifestyle throughout the entire treatment process is also crucial. The Newest Vertical 3 Handles 2450MHz Microwave FrezzeWave Skin Tightening Machine

    Contraindications
    (1) FREEZEWAVE
    Skin diseases (inflammation, infection, hematoma, herpes, etc.).
    Severe vascular disease.
    Patients are at risk of phlebitis or thrombosis, or with a history of phlebitis or thrombosis.
    Any metallic implants in the body, such as pacemakers, metal teeth, stents in the head or other areas.
    Pregnancy and lactation.
    Decompensated Type 1 and Type 2 diabetes.
    Infectious diseases (particularly hepatitis B and hepatitis C).
    Transplanted organs.
    Hemorrhagic diathesis coagulation disorders.

    2. Application
    (1) Localized Fat Deposits: The deep-penetrating probe delivers energy deep into the tissue, disrupting the membranes of subcutaneous fat cells. The dissolved fat is then expelled from the body through stimulated physiological metabolic processes (macrophage lipolysis).
    (2) Cellulite: Precisely targets the connective septa between fat lobules in advanced cellulite (where the typical “orange peel effect” is visible).
    (3) Skin Tightening: Unique microwave energy instantly contracts dermal collagen fibers while stimulating new collagen production, resulting in firmer, more elastic tissue.
    Utilizing microwave energy to reduce stubborn fat, tighten skin, and smooth cellulite. Safe and effective with no downtime.

    Product Maintenance
    (1) Warranty: one year from the date of purchase for the main unit, six months for the treatment handpieces. We are responsible for the maintenance in our factory in GZ. After the warranty period has expired, we will charge a service fee or component fee.
    (2) After treatment, wipe off any gel/essential oil residue from the handpiece using a clean cloth.
    (3) Improper installation, operation, or maintenance of the instrument may cause malfunction of this or other equipment.
    (4) If display malfunctions or other obvious defects occur, immediately turn off the device using the power switch, unplug the power cord, and contact the manufacturer for maintenance. Do not attempt repairs without guidance.
    (5) If the device is not installed immediately upon receipt, store it along with all external components or accessories in their original packaging in a dry location. For long-term storage, place the device in its original packaging and store it indoors in a well-ventilated area free from corrosive substances. 3 In 1 Freezewave Body Contouring Machine
    (6) Do not store the equipment in dusty environments. Do not immerse it in any liquid. Keep it away from running water. Avoid placing the equipment in direct sunlight.
    (7) Prohibited environments for machine operation:
    Humid and hot environments.
    Dusty environments.
    Environments with high levels of smoke, dust, or water vapor.
    (8) Disclaimer:
    Damage caused by fire, earthquake, or war.
    User malfunction or operator error.
    Damage resulting from other purposes (not covered in the manual).
    Operation without manual guidance.

    Physio Wave ElectromagneticTransduction Bone Injuries Arthritis Thoracic Vertebral Pathology Less Pain Equipment  Physio Therapy Magnetica Electromagnetic Transduction Rapid Pain Relief Instrument

    error: BELLEZASTARS Content is protected !!